Show simple item record

dc.contributor.authorParisini, I.
dc.contributor.authorCheng, S. J.
dc.contributor.authorSymons, D. D.
dc.contributor.authorBrown, Marc
dc.contributor.authorKostrzewski, A.
dc.contributor.authorMurnane, D.
dc.date.accessioned2014-06-12T13:00:35Z
dc.date.available2014-06-12T13:00:35Z
dc.date.issued2013-08
dc.identifier.citationParisini , I , Cheng , S J , Symons , D D , Brown , M , Kostrzewski , A & Murnane , D 2013 , ' Assessment of a cyclone-type spacer device for use in dry powder inhalation ' , Journal of Aerosol Medicine and Pulmonary Drug Delivery , vol. 26 , no. 4 , 11 , pp. A5 . https://doi.org/10.1089/jamp.2013.01ab
dc.identifier.issn1941-2711
dc.identifier.urihttp://hdl.handle.net/2299/13725
dc.description.abstractDry powder inhalers (DPIs) are used widely in asthma and chronic obstructive pulmonary disease therapies. However, the lung deposition from DPIs is highly variable and patients with poor lung function can struggle to achieve a sufficient inhalation rate. The aim of this study was to investigate whether a cyclone spacer device could improve the in vitro drug delivery performance of a commercial DPI. The aerosolization of a salbutamol sulphate/lactose blend was studied at 45 Lmin-1 and 60 Lmin-1 using the Cyclohaler (DPI), with and without a Perspex cyclone device which was manufactured in-house. Deposition of particles in the next generation impactor and within the devices was determined by high performance liquid chromatography, and aerosol emission was studied using laser diffraction analysis. The % emission from the DPI was unchanged by the addition of the cyclone at 45 Lmin-1 and 60 Lmin-1. Dose deposition in the cyclone was high at both flow rates, however the fine particle fractions (FPF) as a % of the doses emitted from the DPI were identical with and without the cyclone in place. Comparing the dose depositing in the impactor (equivalent to an inhaled dose), FPFs were substantially higher when the cyclone was employed (e.g. 92.2 ± 7.7% with cyclone vs. 27.9 ± 3.5% without cyclone at 45 Lmin-1). The mass median diameters of particles emitted from the cyclone were also dramatically decreased compared to the DPI alone. This work has shown the potential of employing a cyclone-type spacer to improve inhaled drug delivery.en
dc.format.extent1
dc.language.isoeng
dc.relation.ispartofJournal of Aerosol Medicine and Pulmonary Drug Delivery
dc.titleAssessment of a cyclone-type spacer device for use in dry powder inhalationen
dc.contributor.institutionHealth & Human Sciences Research Institute
dc.contributor.institutionSchool of Life and Medical Sciences
dc.contributor.institutionDepartment of Pharmacy
dc.contributor.institutionCentre for Research into Topical Drug Delivery and Toxicology
dc.contributor.institutionPharmaceutics
dc.contributor.institutionSkin and Nail Group
dc.contributor.institutionAirway Group
dc.contributor.institutionBioadhesive Drug Delivery Group
dc.contributor.institutionNanopharmaceutics
dc.contributor.institutionPharmaceutical Analysis and Product Characterisation
dc.contributor.institutionCentre for Clinical Practice, Safe Medicines and Drug Misuse Research
dc.contributor.institutionLaw, Ethics and Professsionalism in Pharmacy Practice
dc.contributor.institutionPatient and Medicines Safety
dc.contributor.institutionPharmacy Education
dc.contributor.institutionToxicology
dc.description.statusPeer reviewed
rioxxterms.versionofrecord10.1089/jamp.2013.01ab
rioxxterms.typeOther
herts.preservation.rarelyaccessedtrue


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record