GEANT4 simulation of the neutron background of the C6D 6 set-up for capture studies at n-TOF
View/ Open
Author
Žugec, P.
Colonna, N.
Bosnar, D.
Altstadt, S.
Andrzejewski, J.
Audouin, L.
Barbagallo, M.
Bécares, V.
Bečvář, F.
Belloni, F.
Berthoumieux, E.
Billowes, J.
Boccone, V.
Brugger, M.
Calviani, M.
Calviño, F.
Cano-Ott, D.
Carrapiço, C.
Cerutti, F.
Chiaveri, E.
Chin, M.
Cortés, G.
Cortés-Giraldo, M.A.
Diakaki, M.
Domingo-Pardo, C.
Dressler, R.
Duran, I.
Dzysiuk, N.
Eleftheriadis, C.
Ferrari, A.
Fraval, K.
Ganesan, S.
García, A.R.
Giubrone, G.
Gómez-Hornillos, M.B.
Gonçalves, I.F.
González-Romero, E.
Griesmayer, E.
Guerrero, C.
Gunsing, F.
Gurusamy, P.
Heinitz, S.
Jenkins, D. G.
Jericha, E.
Kadi, Y.
Käppeler, F.
Karadimos, D.
Kivel, N.
Koehler, P.
Kokkoris, M.
Krtička, M.
Kroll, J.
Langer, C.
Lederer, C.
Leeb, H.
Leong, L. S.
Lo Meo, S.
Losito, R.
Manousos, A.
Marganiec, J.
Martínez, T.
Massimi, C.
Mastinu, P. F.
Mastromarco, M.
Meaze, M.
Mendoza, E.
Mengoni, A.
Milazzo, P. M.
Mingrone, F.
Mirea, M.
Mondalaers, W.
Paradela, C.
Pavlik, A.
Perkowski, J.
Plompen, A.
Praena, J.
Quesada, J. M.
Rauscher, T.
Reifarth, R.
Riego, A.
Roman, F.
Rubbia, C.
Sarmento, R.
Saxena, A.
Schillebeeckx, P.
Schmidt, S.
Schumann, D.
Tagliente, G.
Tain, J. L.
Tarrío, D.
Tassan-Got, L.
Tsinganis, A.
Valenta, S.
Vannini, G.
Variale, V.
Vaz, P.
Ventura, A.
Versaci, R.
Vermeulen, M. J.
Vlachoudis, V.
Vlastou, R.
Wallner, A.
Ware, T.
Weigand, M.
Weiss, C.
Wright, T.
Attention
2299/13838
Abstract
The neutron sensitivity of the C6D6 detector setup used at n-TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n-TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a natC sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured natC yield has been discovered, which prevents the use of natC data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements. © 2014 Elsevier B.V.
Publication date
2014-10-01Published in
Nuclear Instruments & Methods in Physics Research Section APublished version
https://doi.org/10.1016/j.nima.2014.05.048Other links
http://hdl.handle.net/2299/13838Metadata
Show full item recordRelated items
Showing items related by title, author, creator and subject.
-
High-accuracy U-233(n, f) cross-section measurement at the white-neutron source n_TOF from near-thermal to 1 MeV neutron energy
Calviani, M.; Praena, J.; Abbondanno, U.; Aerts, G.; Alvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Becvar, F.; Belloni, F.; Berthier, B.; Berthoumieux, E.; Calvino, F.; Cano-Ott, D.; Capote, R.; Carrapico, C.; Cennini, P.; Chepel, V.; Chiaveri, E.; Colonna, N.; Cortes, G.; Couture, A.; Cox, J.; Dahlfors, M.; David, S.; Dillmann, I.; Domingo-Pardo, C.; Dridi, W.; Duran, I.; Eleftheriadis, C.; Embid-Segura, M.; Ferrant, L.; Ferrari, A.; Ferreira-Marques, R.; Fujii, K.; Furman, W.; Goncalves, I.; Gonzalez-Romero, E.; Goverdovski, A.; Gramegna, F.; Guerrero, C.; Gunsing, F.; Haas, B.; Haight, R.; Heil, M.; Rauscher, T.; N TOF Collaboration (2009-10)The U-233(n, f) cross section has been measured at the white neutron source n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from similar to 30 meV to 1 MeV neutron energy. ... -
High-resolution neutron capture and transmission measurements, and the stellar neutron-capture cross section of Sr-88 (vol C62, art. no. 055803, 2000)
Koehler, P. E.; Winters, R.R.; Guber, K. H.; Rauscher, T.; Harvey, J. A.; Raman, S.; Spencer, R.R.; Blackmon, J.C.; Larson, D.C.; Bardayan, D.W.; Lewis, T.A. (2001-04) -
Neutron capture cross section measurement of Sm-151 at the CERN neutron time of flight facility (n_TOF)
Abbondanno, U.; Aerts, G.; Alvarez-Velarde, F.; Alvarez-Pol, H.; Andriamonje, S.; Andrzejewski, J.; Badurek, G.; Baumann, P.; Becvar, F.; Benlliure, J.; Berthoumieux, E.; Calvino, F.; Cano-Ott, D.; Capote, R.; Cennini, P.; Chepel, V.; Chiaveri, E.; Colonna, N.; Cortes, G.; Cortina, D.; Couture, A.; Cox, J.; Dababneh, S.; Dahlfors, M.; David, S.; Dolfini, R.; Domingo-Pardo, C.; Duran, R.B.; Embid-Segura, M.; Ferrant, L.; Ferrari, A.; Ferreira-Marques, R.; Frais-Koelbl, H.; Furman, W.; Goncalves, I. F.; Gallino, R.; Gonzalez-Romero, E.; Goverdovski, A.; Gramegna, F.; Griesmayer, E.; Gunsing, F.; Haas, B.; Haight, R.; Heil, M.; Herrera-Martinez, A.; Isaev, S.; Jericha, E.; Kappeler, F.; Kadi, Y.; Rauscher, T.; n TOF Collaboration (2004-10-15)The Sm-151(n,gamma)Sm-152 cross section has been measured at the spallation neutron facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The new facility combines excellent resolution in neutron time-of-flight, ...