dc.description.abstractAdvanced devices that can assist the therapists to offer rehabilitation are in high demand with the growing rehabilitation needs. The primary requirement from such rehabilitative devices is to reduce the therapist monitoring time. If the training device can autonomously adapt to the performance of the user, it can make the rehabilitation partly self-manageable. Therefore the main goal of our research is to investigate how to make a rehabilitation system more adaptable. The strategy we followed to augment the adaptability of the GENTLE/A robotic system was to (i) identify the parameters that inform about the contribution of the user/robot during a human-robot interaction session and (ii) use these parameters as performance indicators to adapt the system. Three main studies were conducted with healthy participants during the course of this PhD. The first study identified that the difference between the position coordinates recorded by the robot and the reference trajectory position coordinates indicated the leading/lagging status of the user with respect to the robot. Using the leadlag model we proposed two strategies to enhance the adaptability of the system. The first adaptability strategy tuned the performance time to suit the user’s requirements (second study). The second adaptability strategy tuned the task difficulty level based on the user’s leading or lagging status (third study). In summary the research undertaken during this PhD successfully enhanced the adaptability of the GENTLE/A system. The adaptability strategies evaluated were designed to suit various stages of recovery. Apart from potential use for remote assessment of patients, the work presented in this thesis is applicable in many areas of human-robot interaction research where a robot and human are involved in physical interaction.en_US
dc.language.isoenen_US
dc.publisherUniversity of Hertfordshireen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectUpper-limb rehabilitationen_US
dc.subjectStrokeen_US
dc.subjectHuman Robot Interactionen_US
dc.subjectAdaptable systemen_US
dc.subjectLead-lag modelen_US
dc.subjectHaptics for rehabilitationen_US
dc.subjectRobot-assisted trainingen_US
dc.subjectAssistive technologiesen_US
dc.subjectBiomechanics of the upper-limben_US
dc.subjectEmbedded-Virtual environmentsen_US
dc.titleGENTLE/A - Adaptive Robotic Assistance for Upper-Limb Rehabilitationen_US
dc.typeinfo:eu-repo/semantics/doctoralThesisen_US
dc.identifier.doi10.18745/th.13895
dc.identifier.doi10.18745/th.13895
dc.type.qualificationlevelDoctoralen_US
dc.type.qualificationnamePhDen_US
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record