Show simple item record

dc.contributor.authorAmirabdollahian, Farshid
dc.contributor.authorJohnson, G.
dc.date.accessioned2016-03-03T10:23:22Z
dc.date.available2016-03-03T10:23:22Z
dc.date.issued2011
dc.identifier.citationAmirabdollahian , F & Johnson , G 2011 , ' Analysis of the results from use of haptic peg-in-hole task for assessment in neurorehabilitation ' , Applied Bionics and Biomechanics , vol. 8 , no. 1 , pp. 1-11 . https://doi.org/10.3233/ABB-2011-0017
dc.identifier.issn1176-2322
dc.identifier.otherPURE: 326874
dc.identifier.otherPURE UUID: df2287ee-7638-426b-809e-52598b4e17fa
dc.identifier.otherScopus: 79959338678
dc.identifier.urihttp://hdl.handle.net/2299/16609
dc.descriptionOriginal article can be found at : http://iospress.metapress.com/ Copyright IOS Press
dc.description.abstractHaptic and robotic technologies have the potential to provide assessment during interaction with humans. This manuscript presents our earlier research during the I-Match project where a haptic peg-in-hole test was used in order to compare between healthy volunteers' performance and those with neurological impairment. Subjects all performed a series of haptic virtual peg-in-hole tasks with varying degrees of difficulty determined by the hole diameter. Haptic instrument, Phantom Desktop 1.5, allowed for recording of biomechanical data which is used to present some variant features between the two subject groups. This paper analyses the placement time, maximum peg transfer velocity, collision forces recorded during peg placement and also insertion accuracy. The first three parameters showed statistically significant differences between the two groups while the last, insertion accuracy, showed insignificant differences (p = 0.152). This is thought to be due to the large clearance value between the smallest hole diameter and the peg. To identify differences between the haptic peg-in-hole and the established NHPT, we are currently in process of conducting a further experiment with a haptic replica of the NHPT test, in order to investigate effects resulting from addition of haptic force feedback compared to the original NHPT test, as well as allowing to explore influences caused by the 1 mm clearance value as originally proposed by Wade.Furthermore, in order to investigate if this method can identify differences between subjects with different neurological conditions, a larger group of subjects with neurological conditions such as stroke, multiple sclerosis, and traumatic brain injury is required to explore potency of this approach for identifying differences between these different conditions.en
dc.language.isoeng
dc.relation.ispartofApplied Bionics and Biomechanics
dc.subjecthaptics
dc.subjecti-match
dc.subjectoutcome measures
dc.subjectpeg-in-hole
dc.subjectrobotic for assessment
dc.titleAnalysis of the results from use of haptic peg-in-hole task for assessment in neurorehabilitationen
dc.contributor.institutionCentre for Computer Science and Informatics Research
dc.contributor.institutionAdaptive Systems
dc.contributor.institutionDepartment of Computer Science
dc.contributor.institutionSchool of Physics, Engineering & Computer Science
dc.contributor.institutionCentre for Future Societies Research
dc.description.statusPeer reviewed
rioxxterms.versionAM
rioxxterms.versionofrecordhttps://doi.org/10.3233/ABB-2011-0017
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record