University of Hertfordshire Research Archive

        JavaScript is disabled for your browser. Some features of this site may not work without it.

        Browse

        All of UHRABy Issue DateAuthorsTitlesThis CollectionBy Issue DateAuthorsTitles

        Arkivum Files

        My Downloads
        View Item 
        • UHRA Home
        • University of Hertfordshire
        • Research publications
        • View Item
        • UHRA Home
        • University of Hertfordshire
        • Research publications
        • View Item

        Agreement among optometrists and ophthalmologists in estimating limbal anterior chamber depth using the van Herick method

        Author
        Jindal, Anish
        Myint, Joy
        Edgar, David F.
        Nolan, Winifred P.
        Lawrenson, John G.
        Attention
        2299/17042
        Abstract
        Purpose: To evaluate the inter-observer agreement for measuring limbal anterior chamber depth (LACD) using the van Herick test in community optometrists, glaucoma specialist optometrists and ophthalmologists. Methods: The study was divided into two phases. In the first phase, a random sample of 100 UK community optometrists were given an opportunity to select and grade eight digital slit-lamp images of anterior chamber angles using the original van Herick 4 point grading scale. The images were included in a clinical decision making study using computerised virtual case vignettes. In the second phase, hospital-based glaucoma specialist optometrists and glaucoma sub-specialist ophthalmologists graded the LACD of the right eye using a 7-point % grading scale in 57 consecutively presenting patients with suspect glaucoma. Inter-observer agreement was assessed using linearly weighted kappa (κw). Results: Inter-observer agreement for community optometrists was moderate, with a mean κw for grading photographic images of 0.50 (95% confidence interval (CI) 0.43-0.57). Overall, ninety-two percent of observations were within one grade of the actual grade, although grading of narrow angles was associated with a 13% false negative error rate (based on a ≤ grade 2 threshold). For Phase 2 of the study, pairwise comparisons between optometrists and ophthalmologists showed that agreement was moderate to substantial (mean κw = 0.54-0.65) with a false negative rate of 1.9% (based on a ≤ 25% threshold). Grading accuracy of specialist optometrists and ophthalmologists were equivalent. Conclusions: In summary, the present study found that community optometrists showed moderate inter-observer agreement for grading LACD. Glaucoma specialist optometrists showed moderate to substantial agreement with weighted kappa values that were equivalent to sub-specialist ophthalmologists. The augmented 7-point % grading scale is intuitive and potentially offers greater accuracy for grading narrow angles than the traditional 4-point scale for grading LACD.
        Publication date
        2015-03
        Published in
        Ophthalmic and Physiological Optics
        Published version
        https://doi.org/10.1111/opo.12199
        Other links
        http://hdl.handle.net/2299/17042
        Metadata
        Show full item record
        Keep in touch

        © 2019 University of Hertfordshire

        I want to...

        • Apply for a course
        • Download a Prospectus
        • Find a job at the University
        • Make a complaint
        • Contact the Press Office

        Go to...

        • Accommodation booking
        • Your student record
        • Bayfordbury
        • KASPAR
        • UH Arts

        The small print

        • Terms of use
        • Privacy and cookies
        • Criminal Finances Act 2017
        • Modern Slavery Act 2015
        • Sitemap

        Find/Contact us

        • T: +44 (0)1707 284000
        • E: ask@herts.ac.uk
        • Where to find us
        • Parking
        • hr
        • qaa
        • stonewall
        • AMBA
        • ECU Race Charter
        • disability confident
        • AthenaSwan