Show simple item record

dc.contributor.authorLiu, X
dc.contributor.authorZhang, X
dc.contributor.authorLu, T
dc.contributor.authorMahkamov, K
dc.contributor.authorWu, Hongwei
dc.contributor.authorMirzaeian, M
dc.date.accessioned2017-06-21T16:32:38Z
dc.date.available2017-06-21T16:32:38Z
dc.date.issued2016-06-25
dc.identifier.citationLiu , X , Zhang , X , Lu , T , Mahkamov , K , Wu , H & Mirzaeian , M 2016 , ' Numerical Simulation of Sub-cooled Boiling Flow with Fouling Deposited inside Channels ' , Applied Thermal Engineering , vol. 103 , pp. 434-442 . https://doi.org/10.1016/j.applthermaleng.2016.04.041
dc.identifier.issn1359-4311
dc.identifier.urihttp://hdl.handle.net/2299/18374
dc.descriptionThis document is the Accepted Manuscript version of the following article: X. Liu, X. Zhang, T. Lu, K. Mahkamov, H. Wu, and M. Mirzaeian 'Numerical simulation of sub-cooled boiling flow with fouling deposited inside channels', Applied Thermal Engineering, Vol. 203, pp. 434-442, June 2016. The version of record is available online at doi: https://doi.org/10.1016/j.applthermaleng.2016.04.041. © 2016 Elsevier Ltd. All rights reserved.
dc.description.abstractIn this article, a numerical simulation has been performed to investigate the sub-cooled boiling flow in axisymmetric channels using the two-phase particle model. The equivalent diameter of the channel is 4.38 mm with 365.7 cm in length. The fouling deposited layer is filled with subsequent two-thirds of the flow channel. The internal surface of the channel is covered by a fouling deposit layer with a thickness ranging from 0.225 mm to 1.55 mm. Uniform heat flux of 29267.6 W/m2 is applied on the heated wall. Validation of the CFD model is carried out through comparison with open published experimental data and a close agreement is achieved. A new parameter, Security factor, is introduced and defined in the current study. Numerical results show that the developed two-phase particle model could well predict the water-steam two-phase change flow. The Nusselt number in the fouling region without fouling deposited could be 50 times higher than that with fouling layer. The heat transfer performance of the channel with thickness of 0.225 mm fouling deposit layer is 5 times larger than that with thickness of 1.55 mm fouling deposit layer. It is also found that the inlet velocity has significant impact on the boiling and total pressure drops along the channel.en
dc.format.extent9
dc.format.extent1300566
dc.language.isoeng
dc.relation.ispartofApplied Thermal Engineering
dc.subjectsub-cooled
dc.subjectnumerical simulation
dc.subjectboiling
dc.subjectfouling
dc.subjectheat transfer
dc.titleNumerical Simulation of Sub-cooled Boiling Flow with Fouling Deposited inside Channelsen
dc.contributor.institutionCentre for Climate Change Research (C3R)
dc.contributor.institutionSchool of Physics, Engineering & Computer Science
dc.contributor.institutionDepartment of Engineering and Technology
dc.contributor.institutionCentre for Engineering Research
dc.contributor.institutionEnergy and Sustainable Design Research Group
dc.description.statusPeer reviewed
dc.date.embargoedUntil2017-04-15
rioxxterms.versionofrecord10.1016/j.applthermaleng.2016.04.041
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record