Show simple item record

dc.contributor.authorCoudron, Loic
dc.contributor.authorMcDonnell, M.B.
dc.contributor.authorMunro, Ian
dc.contributor.authorMcCluskey, Daniel
dc.contributor.authorJohnston, Ian
dc.contributor.authorTan, Christabel
dc.contributor.authorTracey, Mark
dc.date.accessioned2019-01-16T13:45:17Z
dc.date.available2019-01-16T13:45:17Z
dc.date.issued2019-03-01
dc.identifier.citationCoudron , L , McDonnell , M B , Munro , I , McCluskey , D , Johnston , I , Tan , C & Tracey , M 2019 , ' Fully integrated digital microfluidics platform for automated immunoassay; a versatile tool for rapid, specific detection of a wide range of pathogens ' , Biosensors & Bioelectronics , vol. 128 , pp. 52-60 . https://doi.org/10.1016/j.bios.2018.12.014
dc.identifier.issn0956-5663
dc.identifier.otherORCID: /0000-0001-9696-3191/work/62748190
dc.identifier.otherORCID: /0000-0001-9199-938X/work/113023237
dc.identifier.urihttp://hdl.handle.net/2299/20972
dc.description© 2018 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence http://creativecommons.org/licenses/by-nc-nd/4.0/.
dc.description.abstractWith the tangible threat posed by the release of chemical and biological warfare (CBW) agents, detection of airborne pathogens is a critical military and security concern. Recent air sampling techniques developed for biocollection take advantage of Electrowetting on Dielectric (EWOD) to recover material, producing highly concentrated droplet samples. Bespoke EWOD-based digital microfluidics platforms are very well suited to take full advantage of the microlitre concentrated droplet resulting from this recovery process. In this paper we present a free-standing, fully automated DMF platform for immunoassay. Using this system, we demonstrate the automated detection of four classes of CBW agent simulant biomolecules and organisms each representing credible threat agents. Taking advantage of the full magnetic separation process with antibody-bound microbeads, rapid and complete separation of specific target antigen can be achieved with minimal washing steps allowing for very rapid detection. Here, we report clear detection of four categories of antigens achieved with assay completion times of between six and ten minutes. Detection of HSA, Bacillus atrophaeus (BG spores), MS2 bacteriophage and Escherichia coli are demonstrated with estimated limit of detection of respectively 30 ng ml -1, 4 × 10 4 cfu ml -1, 10 6 pfu ml -1 and 2 × 10 7 cfu ml -1. The fully-integrated portable platform described in this paper is highly compatible with the next generation of electrowetting-coupled air samplers and thus shows strong potential toward future in-field deployable biodetection systems and could have key implication in life-changing sectors such as healthcare, environment or food security.en
dc.format.extent9
dc.format.extent1570999
dc.language.isoeng
dc.relation.ispartofBiosensors & Bioelectronics
dc.subjectBiodetection
dc.subjectDigital microfluidics
dc.subjectElectrowetting
dc.subjectImmunoassay
dc.subjectInstrumentation
dc.subjectLab-on-a-chip
dc.subjectBiotechnology
dc.subjectBiophysics
dc.subjectBiomedical Engineering
dc.subjectElectrochemistry
dc.titleFully integrated digital microfluidics platform for automated immunoassay; a versatile tool for rapid, specific detection of a wide range of pathogensen
dc.contributor.institutionSchool of Engineering and Technology
dc.contributor.institutionCentre for Engineering Research
dc.contributor.institutionCentre for Research in Biodetection Technologies
dc.contributor.institutionMicro Electro-Mechanical Systems
dc.contributor.institutionMicrofluidics and Microengineering
dc.contributor.institutionBioEngineering
dc.contributor.institutionCentre for Hazard Detection and Protection Research
dc.contributor.institutionExtracellular Vesicle Research Unit
dc.contributor.institutionDepartment of Engineering and Technology
dc.description.statusPeer reviewed
dc.date.embargoedUntil2019-12-18
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85059577500&partnerID=8YFLogxK
rioxxterms.versionofrecord10.1016/j.bios.2018.12.014
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record