Show simple item record

dc.contributor.authorDalton, Christopher
dc.contributor.authorHall, Charlotte
dc.contributor.authorLydon, Helen
dc.contributor.authorJenner, John
dc.contributor.authorChipman, J Kevin
dc.contributor.authorGraham, John S
dc.contributor.authorChilcott, Robert P
dc.date.accessioned2019-08-21T15:07:42Z
dc.date.available2019-08-21T15:07:42Z
dc.date.issued2018-06-01
dc.identifier.citationDalton , C , Hall , C , Lydon , H , Jenner , J , Chipman , J K , Graham , J S & Chilcott , R P 2018 , ' The percutaneous absorption of soman in a damaged skin porcine model and the evaluation of WoundStat™ as a topical decontaminant ' , Cutaneous and Ocular Toxicology , vol. 37 , no. 2 , pp. 172-179 . https://doi.org/10.1080/15569527.2017.1365883
dc.identifier.issn1556-9527
dc.identifier.urihttp://hdl.handle.net/2299/21619
dc.description.abstractPURPOSE: The aim of this study was to evaluate a candidate haemostat (WoundStat™), down-selected from previous in vitro studies, for efficacy as a potential skin decontaminant against the chemical warfare agent pinacoyl methylfluorophosphonate (Soman, GD) using an in vivo pig model. MATERIALS AND METHODS: An area of approximately 3 cm2 was dermatomed from the dorsal ear skin to a nominal depth of 100 µm. A discrete droplet of 14C-GD (300 µg kg-1) was applied directly onto the surface of the damaged skin at the centre of the dosing site. Animals assigned to the treatment group were given a 2 g application of WoundStat™ 30 s after GD challenge. The decontamination efficacy of WoundStat™ against GD was measured by the direct quantification of the distribution of 14C-GD, as well as routine determination of whole blood cholinesterase and physiological measurements. RESULTS: WoundStat™ sequestered approximately 70% of the applied 14C-GD. Internal radiolabel recovery from treated animals was approximately 1% of the initially applied dose. Whole blood cholinesterase levels decreased to less than 10% of the original value by 15 min post WoundStat™ treatment and gradually decreased until the onset of apnoea or until euthanasia. All treated animals showed signs of GD intoxication that could be grouped into early (mastication, fasciculations and tremor), intermediate (miosis, salivation and nasal secretions) and late onset (lacrimation, body spasm and apnoea) effects. Two of the six WoundStat™ treated animals survived the study duration. CONCLUSIONS: The current study has shown that the use of WoundStat™ as a decontaminant on damaged pig ear skin was unable to fully protect against GD toxicity. Importantly, the findings indicate that the use of WoundStat™ in GD contaminated wounds would not exacerbate GD toxicity. These data suggest that absorbent haemostatic products may offer some limited functionality as wound decontaminants.en
dc.format.extent8
dc.format.extent200199
dc.language.isoeng
dc.relation.ispartofCutaneous and Ocular Toxicology
dc.subjectchemical warfare agent
dc.subjectcontaminated wound
dc.subjectdecontamination
dc.subjectSoman
dc.subjectWoundStat™
dc.subjectToxicology
dc.titleThe percutaneous absorption of soman in a damaged skin porcine model and the evaluation of WoundStat™ as a topical decontaminanten
dc.contributor.institutionSchool of Life and Medical Sciences
dc.contributor.institutionCentre for Applied Clinical, Health and Care Research (CACHE)
dc.contributor.institutionToxicology
dc.contributor.institutionDepartment of Clinical, Pharmaceutical and Biological Science
dc.contributor.institutionCentre for Research into Topical Drug Delivery and Toxicology
dc.contributor.institutionPharmaceutics
dc.description.statusPeer reviewed
dc.date.embargoedUntil2018-08-30
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85028531451&partnerID=8YFLogxK
rioxxterms.versionofrecord10.1080/15569527.2017.1365883
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record