        Multiscale Tomography: Probing The Nano-, Micro-, And Meso-Scale Resolution Of Inhalation Powder Structure

        View/Open
        Gajjar_Styliari_RDD_Europe_2019.pdf (PDF, 6Mb)
        Author
        Gajjar, Parmesh
        Styliari, Ioanna Danai
        Burnett, Timothy
        Chen, Xizhong
        Elliot, James A.
        Ganley, William J.
        Hammond, Robbert
        Nguyen, Hien
        Price, Robert
        Roberts, Kevin
        Withers, Philip
        Murnane, Darragh
        Attention
        2299/22750
        Abstract
        Understanding the agglomeration behavior of inhaled formulations is essential to ensure consistent aerosolization performance that maximizes drug deposition in the lower respiratory tract. Although many techniques are currently used to characterize critical material attributes (CMAs) such as the particle size distribution (PSD), these techniques suffer from low resolution, image in 2D projections, or are based on shape assumptions. Bearing in mind the importance of the powder microstructure, this work introduces the use of x-ray computed tomography (XCT) as a non- destructive, multiscale technique for characterizing inhalation formulations. Different grades of inhalation and tableting grade lactose have been analyzed using XCT, with distributions for size (volume weighted) and sphericity extracted and compared with laser diffraction and optical microscopy. The three-dimensional information provided from XCT provides a more accurate assessment of powder size and shape, demonstrating the promise for XCT as a valuable powder characterization technique that provides information about the powder microstructure, a descriptor now required from the U.S. Food and Drug Administration (Q3 equivalence).
        Publication date
        2019-05-07
        Published in
        RDD Europe 2019
        Other links
        http://hdl.handle.net/2299/22750
        Metadata
        Show full item record
        Keep in touch

        © 2019 University of Hertfordshire

        I want to...

        • Apply for a course
        • Download a Prospectus
        • Find a job at the University
        • Make a complaint
        • Contact the Press Office

        Go to...

        • Accommodation booking
        • Your student record
        • Bayfordbury
        • KASPAR
        • UH Arts

        The small print

        • Terms of use
        • Privacy and cookies
        • Criminal Finances Act 2017
        • Modern Slavery Act 2015
        • Sitemap

        Find/Contact us

        • T: +44 (0)1707 284000
        • E: ask@herts.ac.uk
        • Where to find us
        • Parking
        • hr
        • qaa
        • stonewall
        • AMBA
        • ECU Race Charter
        • disability confident
        • AthenaSwan