dc.contributor.author | Tounsi, Mahmoud Mostefa | |
dc.contributor.author | Allali, Ahmed | |
dc.contributor.author | Merabet Boulouiha , Houari | |
dc.contributor.author | Denai, Mouloud | |
dc.date.accessioned | 2021-01-29T12:30:03Z | |
dc.date.available | 2021-01-29T12:30:03Z | |
dc.date.issued | 2021-06 | |
dc.identifier.citation | Tounsi , M M , Allali , A , Merabet Boulouiha , H & Denai , M 2021 , ' ANFIS control of a shunt active filter based with a five-level NPC inverter to improve power quality ' , International Journal of Electrical and Computer Engineering (IJECE) , vol. 11 , no. 3 , pp. 1886-1893 . https://doi.org/10.11591/ijece.v11i3.pp1886-1893 | |
dc.identifier.issn | 2088-8708 | |
dc.identifier.uri | http://hdl.handle.net/2299/23804 | |
dc.description | © 2021 The Author(s). This is an open access article under the CC BY-SA license (https://creativecommons.org/licenses/by-sa/4.0/). | |
dc.description.abstract | This paper addresses the problem of power quality, and the degradation of the current waveform in the distribution network which results directly from the proliferation of the nonlinear loads. We propose to use a five-level Neutral Point Clamped (NPC) inverter topology for the implementation of the shunt active filter (SAPF). The aim of the SAPF is to inject harmonic currents in phase opposition at the connection point. The identification of harmonics is based on the pq method. A neuro-fuzzy controller based on ANFIS (Adaptive Neuro Fuzzy Inference System) is designed for the SAPF. The simulation study is carried out using MATLAB/Simulink and the results show a significant improvement in the quality of energy and a reduction in Total Harmonic Distortion (THD) in accordance with IEC standard, IEEE-519, IEC 61000, EN 50160. | en |
dc.format.extent | 8 | |
dc.format.extent | 805683 | |
dc.language.iso | eng | |
dc.relation.ispartof | International Journal of Electrical and Computer Engineering (IJECE) | |
dc.subject | ANFIS; harmonic; multilevel inverter; nonlinear load; power quality; p-q method; SAPF | |
dc.title | ANFIS control of a shunt active filter based with a five-level NPC inverter to improve power quality | en |
dc.contributor.institution | Centre for Engineering Research | |
dc.contributor.institution | Communications and Intelligent Systems | |
dc.contributor.institution | School of Physics, Engineering & Computer Science | |
dc.contributor.institution | Department of Engineering and Technology | |
dc.description.status | Peer reviewed | |
rioxxterms.versionofrecord | 10.11591/ijece.v11i3.pp1886-1893 | |
rioxxterms.type | Journal Article/Review | |
herts.preservation.rarelyaccessed | true | |