dc.contributor.author | Tang, Winnie | |
dc.contributor.author | Plank, Claire | |
dc.contributor.author | Kiepura, Claire | |
dc.contributor.author | Bunting, Sharon | |
dc.contributor.author | Waugh, Jodie | |
dc.contributor.author | Coates, Matthew | |
dc.contributor.author | Spencer, Neil | |
dc.contributor.author | Barlow, Andrew | |
dc.contributor.author | Mogal, Rahul | |
dc.contributor.author | Maddox, Anthony | |
dc.date.accessioned | 2021-05-11T23:09:19Z | |
dc.date.available | 2021-05-11T23:09:19Z | |
dc.date.issued | 2021-07-31 | |
dc.identifier.citation | Tang , W , Plank , C , Kiepura , C , Bunting , S , Waugh , J , Coates , M , Spencer , N , Barlow , A , Mogal , R & Maddox , A 2021 , ' Rapid onsite evaluation uses a very small proportion of total material aspirated at endobronchial or endoscopic ultrasound in the investigation of suspected thoracic malignancy ' , Cytopathology , vol. 32 , no. 4 , pp. 416-427 . https://doi.org/10.1111/cyt.12963 | |
dc.identifier.issn | 1365-2303 | |
dc.identifier.uri | http://hdl.handle.net/2299/24479 | |
dc.description | © 2021 John Wiley & Sons Ltd. This is the accepted manuscript version of an article which has been published in final form at https://doi.org/10.1111/cyt.12963 | |
dc.description.abstract | Introduction The objectives were: to measure the proportion of aspirated material used to make direct slides for rapid onsite evaluation (ROSE) at endobronchial (EBUS) and endoscopic ultrasound (EUS) in suspected thoracic malignancy; and to correlate pass weights with ROSE category and needle size. Method All EBUS and EUS cases for possible thoracic malignancy October 2018‐May 2019 were included. All material from each pass was expelled into a Petri dish. One drop of material was placed on each of two slides; one used for ROSE, the other fixed and remaining material processed to cell block. Dish and slides were weighed before and after this procedure on a sensitive balance and weight of aspirate and slide material calculated. When ROSE identified malignancy, slide production ceased but target sampling for ancillary studies continued. Results ROSE accuracy was 96.8%. Mean percentage by target of aspirated material used to make direct slides for ROSE was 1.9% in malignant cases and 3.6% in non‐malignant cases (P = .027 for difference). Mean percentage by pass was 5.9%. Mean weight of a single aspirate was 128.8 mg. Mean weight of aspirates insufficient on ROSE (175.7 mg) was significantly higher than the mean weight of benign or malignant aspirates (117.1 and 114.0 mg, respectively). Mean weight of aspirates using 22G needles (132.6 mg) was significantly higher than that for 25G needles (87.1 mg). Conclusion Material made into direct slides at EBUS and EUS and used in part for ROSE uses a tiny proportion of aspirated material with over 98% processed to cell block and available for ancillary testing in malignant cases. | en |
dc.format.extent | 12 | |
dc.format.extent | 752317 | |
dc.language.iso | eng | |
dc.relation.ispartof | Cytopathology | |
dc.subject | endobronchial ultrasound | |
dc.subject | rapid on-site evaluation | |
dc.subject | rapid onsite evaluation | |
dc.subject | sample weight | |
dc.subject | specimen handling | |
dc.subject | thoracic neoplasms | |
dc.subject | Pathology and Forensic Medicine | |
dc.subject | Histology | |
dc.title | Rapid onsite evaluation uses a very small proportion of total material aspirated at endobronchial or endoscopic ultrasound in the investigation of suspected thoracic malignancy | en |
dc.contributor.institution | Statistical Services Consulting Unit | |
dc.contributor.institution | Managing Complex Change Research Group | |
dc.contributor.institution | Hertfordshire Business School | |
dc.description.status | Peer reviewed | |
dc.date.embargoedUntil | 2022-03-26 | |
dc.identifier.url | http://www.scopus.com/inward/record.url?scp=85103121890&partnerID=8YFLogxK | |
rioxxterms.versionofrecord | 10.1111/cyt.12963 | |
rioxxterms.type | Journal Article/Review | |
herts.preservation.rarelyaccessed | true | |