Show simple item record

dc.contributor.authorXie, Yongqi
dc.contributor.authorFang, Zhen
dc.contributor.authorZhang, Hongxing
dc.contributor.authorWu, Hongwei
dc.contributor.authorLiu, Siyuan
dc.date.accessioned2022-11-28T16:45:02Z
dc.date.available2022-11-28T16:45:02Z
dc.date.issued2022-11-25
dc.identifier.citationXie , Y , Fang , Z , Zhang , H , Wu , H & Liu , S 2022 , ' Visualization study on operating performance of a dual compensation chamber loop heat pipe under acceleration condition ' , Applied Thermal Engineering , vol. 217 , 119157 . https://doi.org/10.1016/j.applthermaleng.2022.119157
dc.identifier.issn1359-4311
dc.identifier.urihttp://hdl.handle.net/2299/25924
dc.description© 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license. https://creativecommons.org/licenses/by/4.0/
dc.description.abstractIn this article, a novel visual dual compensation chamber loop heat pipe (DCCLHP) under acceleration conditions was experimentally investigated. The working fluid was deionized water and the wick material was sintered nickel powder. Visual windows were installed on both compensation chambers (CCs) and condenser in order to observe the vapor and liquid distribution. The operating performance and physical mechanism of the proposed DCCLHP under both acceleration direction A and B at different heat loads and acceleration magnitudes were analysed in a systematic manner. Direction A refers the acceleration direction which was parallel to the axis of the evaporator and the CC without a bayonet placed at the outer edge of the rotating arm. While direction B is defined as the acceleration direction was perpendicular to the axis of the evaporator and the evaporator was placed at the outer edge of the rotating arm. In the current study, the heat load varies from 30 W to 130 W and the acceleration magnitude ranges from 1 g to 15 g. Experimental results revealed that: (i) The larger the heat load, the higher the operating temperature. Obviously waving of the vapor-liquid interface in the CC is observed at direction A. Bubbles generated in the CCs and the vapor-liquid interface moves back and forth in the condenser during temperature oscillation at both 70 W and 90 W for the case of 13 g and direction B. (ii) Under direction B, the DCCLHP presents lower operating temperature and higher thermal conductance. The maximum temperature is 143.2 °C at 5 g and 90 W under direction A. The maximum thermal conductance is 1.70 W/K at 13 g and 130 W under direction B. (iii) In general, the operating temperature shows a trend of decreasing first and then increasing with the increase of acceleration. Whereas the thermal conductance shows an opposite behavior. The transition acceleration, namely the acceleration magnitude at the minimum temperature, is 13 g for the case of direction A. However, under direction B, the large heat load can result in a large transition acceleration. (iv) Intermittent spattering of liquid drops is observed in the CCs at 70 W and 15 g under direction A. The flow pattern under direction A is different with that under direction B at each heat load. Multiple segments of the liquid and vapor phase alternately distribute and stratified flow forms in the condenser.en
dc.format.extent14
dc.format.extent20659665
dc.language.isoeng
dc.relation.ispartofApplied Thermal Engineering
dc.subjectAcceleration field
dc.subjectDual compensation chamber
dc.subjectElectronics cooling
dc.subjectLoop heat pipe
dc.subjectVisualization
dc.subjectEnergy Engineering and Power Technology
dc.subjectIndustrial and Manufacturing Engineering
dc.titleVisualization study on operating performance of a dual compensation chamber loop heat pipe under acceleration conditionen
dc.contributor.institutionCentre for Engineering Research
dc.contributor.institutionEnergy and Sustainable Design Research Group
dc.contributor.institutionCentre for Climate Change Research (C3R)
dc.contributor.institutionSchool of Physics, Engineering & Computer Science
dc.contributor.institutionDepartment of Engineering and Technology
dc.description.statusPeer reviewed
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85136083644&partnerID=8YFLogxK
rioxxterms.versionofrecord10.1016/j.applthermaleng.2022.119157
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue