Abstract
Wind energy conversion systems have become an important part of renewable energy history due to their accessibility and cost-effectiveness. Offshore wind farms are seen as the future of wind energy, but they can be very expensive to maintain if faults occur. To achieve a reliable and consistent performance, modern wind turbines require advanced fault detection and diagnosis methods. The current research introduces a proposed active fault-tolerant control (AFTC) system that uses backstepping active disturbance rejection theory (BADRC) and an adaptive neurofuzzy system (ANFIS) detector in combination with principal component analysis (PCA) to compensate for system disturbances and maintain performance even when a generator actuator fault occurs. The simulation outcomes demonstrate that the suggested method successfully addresses the actuator generator torque failure problem by isolating the faulty actuator, providing a reliable and robust solution to prevent further damage. The neurofuzzy detector demonstrates outstanding performance in detecting false data in torque, achieving a precision of (Formula presented.) for real data and (Formula presented.) for false data. With a recall of (Formula presented.), no false negatives were observed. The overall accuracy of (Formula presented.) highlights the detector’s ability to reliably classify data as true or false. These findings underscore the robustness of the detector in detecting false data, ensuring the accuracy and reliability of the application presented. Overall, the study concludes that BADRC and ANFIS detection and isolation can improve the reliability of offshore wind farms and address the issue of actuator generator torque failure.
Publication date
2023-07-18Published in
EnergiesPublished version
https://doi.org/10.3390/en16145455Other links
http://hdl.handle.net/2299/26788Metadata
Show full item recordRelated items
Showing items related by title, author, creator and subject.
-
New transformation for efficient DSP control of active power-line conditioners
Cheng, L.; Cheung, R.; Sotudeh, R. (1996) -
Fuzzy Control of a Three-Phase Shunt Active Filter for Harmonic Current Compensation in Wind-Diesel Standalone System
Kouadria, Mohamed Abdeldjabbar; Allaoui, Tayeb; Denai, Mouloud (2016)This paper presents the design of a fuzzy controller for a three-phase shunt active filter integrated in wind-diesel power system equipped with a wind turbine driving an induction generator. The goal for this controller ... -
Feasibility of high-intensity interval training and moderate-intensity continuous training in adults with inactive or mildly active Crohn’s disease: : Study protocol for a randomised controlled trial
Tew, Garry; Carpenter, Roger; Seed, Michael; Anderson, Simon; Langmead, Louise; Fairhurst, Caroline; Bottoms, Lindsay (2017-04-03)Background: Structured exercise training has been proposed as a useful adjunctive therapy for Crohn’s disease because it may counteract some disease-specific complications by improving immune function and psychological ...