The Development and Validation of the HPLC Method for Determination of Artesunate and Amodiaquine in Novel Antimalarial Formulations
Abstract
ASAQ combination drug used in treating malaria is bitter in taste, resulting in poor adherence and difficulty in swallowing by children. To mitigate this issue, taste masking is achieved by coating the drug with polymers to improve the taste of the dosage form. However, this produces a novel drug product which must undergo analytical evaluation to ensure that it is safe and drug content matches the label claim. The aim of this study is to develop and validate a novel analytical methodology which is suitable for this purpose.
Thus, a reversed phase high performance liquid chromatography for the quantitative determination of AS and its impurities was developed. The method was validated according to ICH guidelines for linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ). The method was found accurate and precise with an average retention time of 8.2 min. Good linearity was observed in the concentration range of 0.25 – 0.75 mg/ml with regression coefficient of r2 =0.999. The assay of the proposed method was found to be 101.5%. The recoveries of artesunate were found to be within 99% - 102%. The % RSD for precision was found to be <2%. Specificity was done to check potential interferences with excipients and degradation products and none of the retention times were interfering with artesunate peak.
A gradient method was developed for quantification of amodiaquine and its impurities. The method was validated according to ICH guidelines for linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ). The method was found accurate and precise with an average retention time of 13.75min. Good linearity was observed in the range of 0.075 – 0.225 mg/ml with regression coefficient of r2 =0.999. The assay of the proposed method was found to be 106.5%. The recoveries of artesunate were found to be within 98% - 102%. The % RSD from repeatability, intra and inter day precisions was found to be <2.0%. Specificity was done to check potential interferences with excipients and degradation products.
Publication date
2024-07-03Funding
Default funderDefault project
Other links
http://hdl.handle.net/2299/28180Metadata
Show full item recordThe following license files are associated with this item:
Related items
Showing items related by title, author, creator and subject.
-
Continuous Steepest Descent Path for Traversing Non-Convex Regions
Beddiaf, Salah (2016-05-12)In this thesis, we investigate methods of finding a local minimum for unconstrained problems of non-convex functions with n variables, by following the solution curve of a system of ordinary differential equations. The ... -
Use of mixed gas pneumoperitoneum during minimally invasive surgery: a systematic review of human and mouse modelled laparoscopic interventions
Chen, Leon; Dasgupta, Prokar; Vasdev, Nikhil (2024-05-17)The formation of pneumoperitoneum involves the process of inflating the peritoneal cavity during laparoscopic and typically uses CO2 as the insufflation gas. This review aims to identify ideal gas mixtures for establishing ... -
A comparison of methods for traversing regions of non-convexity in optimization problems
Bartholomew-Biggs, Michael; Beddiaf, Salah; Christianson, Bruce (2019-11-13)This paper considers the well-known problem of dealing with non-convexity during the minimization of a non-linear function f(x) by Newton-like methods. The proposal made here involves a curvilinear search along an approximation ...