Chest Radiograph Interpretation with Deep Learning
Abstract
Chest radiographs are one of the most commonly used diagnostic modalities in healthcare due to their
effectiveness in detecting conditions related to the thoracic region. However, the increasing demand
for radiological services, coupled with a shortage of radiologists and the potential for diagnostic errors,
demands innovative solutions. The integration of artificial intelligence (AI) and deep learning techniques
offers a promising approach to support radiology professionals and enhance the diagnostic accuracy and
efficiency of the diagnostic process. This thesis addresses the challenge of improving the performance
of deep learning models for multi-label classification of chest radiographs using the CheXpert dataset. It
focuses on both model-centric and data-centric methods, specifically techniques such as Gaussian Mixture
Models (GMM) for relabeling uncertain labels, multi-scale template matching for focused learning, a
custom pooling layer for better feature extraction, and Sequential Multi-Label Enrichment (SMLE) for
improved detection of coexisting conditions. The primary objective is to enhance the reliability and
performance of AI models in chest radiograph interpretation by developing new model- and data-centric
methods. This research aims to improve uncertain label handling, overall classification performance,
and the detection of multiple coexisting conditions.
The study employs convolutional neural networks (CNNs), DenseNet121, and Swin Transformers to
investigate the effects of excluding versus relabeling uncertain labels. It also evaluates the efficacy of a
custom pooling layer for classification performance and the effectiveness of theSMLEDenseNet model on
co-existing conditions. Significant performance improvements are demonstrated when uncertain labels
are appropriately handled using GMM. The custom pooling layer significantly enhances the classification
performance of the model, and the SMLE DenseNet model outperforms the baseline DenseNet121 in
detecting co-existing conditions. Finally, the study also examines radiologist’s shift in perception towards
the integration of AI in clinical practice through pre- and post-presentation questionnaires. The findings
indicate a generally positive attitude shift towards AI. Despite concerns regarding the deskilling of new
radiology professionals, radiologists recognize the potential of AI models to enhance the efficiency of
radiology departments and patient care.
This research contributes insights into the practical implementation of AI in medical imaging. It
shows that advanced techniques can significantly improve the diagnostic performance and efficiency of
AI models. The findings also emphasize the importance of addressing radiologist’s concerns to ensure
the successful integration of AI into clinical practice.
Publication date
2024-08-19Funding
Default funderDefault project
Other links
http://hdl.handle.net/2299/28479Metadata
Show full item recordThe following license files are associated with this item:
Related items
Showing items related by title, author, creator and subject.
-
Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool?
Doherty, P.; O'Leary, D.; Brennan, Patrick C. (2003-08-01)Increasing beam energies are well established as a radiation dose-reducing tool in diagnostic radiology. This has led to useful recommendations by the Commission of European Communities (CEC) for appropriate kVp values to ... -
A comparison of mean glandular dose diagnostic reference levels within the all-digital irish national breast screening programme and the Irish symptomatic breast services
O'Leary, Desiree; Rainford, Louise (2013-03-01)Data on image quality, compression and radiation dose were collected from symptomatic breast units within the Republic of Ireland. Quantitative and qualitative data were analysed using SPSS. Recommendations of mean glandular ... -
Increasing film-focus distance (FFD) reduces radiation dose for x-ray examinations
Brennan, Patrick C.; McDonnell, S.; O'Leary, D. (2004-04-21)Increasing film-focus distance (FFD) from the traditional 100 cm has been shown to be an effective method of reducing dose whilst maintaining image quality. In particular, previous work increasing the FFD from 100 to 130 ...