dc.identifier.citationXie , Y , Fang , Z , Wei , J , Wu , H , Zhang , H & Li , G 2025 , ' Design and experimental study of a dual compensation chamber flat loop heat pipe for electronic devices ' , International Journal of Heat and Mass Transfer , vol. 241 , 126707 , pp. 1-18 . https://doi.org/10.1016/j.ijheatmasstransfer.2025.126707
dc.identifier.issn0017-9310
dc.identifier.urihttp://hdl.handle.net/2299/28725
dc.description© 2025 Elsevier Ltd. All rights are reserved. This is the accepted manuscript version of an article which has been published in final form at https://doi.org/10.1016/j.ijheatmasstransfer.2025.126707
dc.description.abstractIn this article, a novel flat loop heat pipe with dual compensation chamber was designed and manufactured to address the heat dissipation challenges of high-power electronic devices operating in various orientations. Ammonia was selected as the working fluid, with stainless steel used for the casing material. The capillary wick consisted of a combination of a wire mesh and a sintered nickel wick. A theoretical analysis was performed based on the distribution of the working fluid in the two compensation chambers, identifying three possible thermodynamic processes for the flat loop heat pipe. The startup and heat transfer performance were experimentally evaluated under six different orientations and varying heat sink temperatures. Experimental results indicated that: (1) the flat loop heat pipe successfully starts and reaches a steady state at 100 W in all orientations, with gravity influencing the startup process by altering the working fluid distribution in the two compensation chambers; (2) at a heat sink temperature of 20 °C, the maximum heat transfer capacity reaches 500 W, while the minimum thermal resistance is 0.059 °C/W at 450 W; (3) when the heat load exceeds 250 W, the impact of orientation on operating temperature and thermal resistance becomes negligible; and (4) the flat loop heat pipe has excellent transient response performance under varying heat loads. These finding provide valuable insights for the application of flat loop heat pipes in avionics devices with complex and variable orientations.en
dc.format.extent18
dc.format.extent11122861
dc.language.isoeng
dc.relation.ispartofInternational Journal of Heat and Mass Transfer
dc.titleDesign and experimental study of a dual compensation chamber flat loop heat pipe for electronic devicesen
dc.contributor.institutionCentre for Future Societies Research
dc.contributor.institutionCentre for Climate Change Research (C3R)
dc.contributor.institutionDepartment of Engineering and Technology
dc.contributor.institutionSchool of Physics, Engineering & Computer Science
dc.contributor.institutionEnergy and Sustainable Design Research Group
dc.contributor.institutionCentre for Engineering Research
dc.description.statusPeer reviewed
dc.date.embargoedUntil2027-01-14
rioxxterms.versionofrecord10.1016/j.ijheatmasstransfer.2025.126707
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record