Search
Now showing items 1-3 of 3
Observations of fluorescent and biological aerosol at a high-altitude site in Central France
(2013-03-27)
Total bacteria, fungal spore and yeast counts were compared with UV Light-Induced Fluorescence (UV-LIF) measurements of ambient aerosol at the summit of the Puy de Dˆome (pdD) mountain in Central France (1465 ma.s.l), which ...
The fluorescence properties of aerosol larger than 0.8 mu m in urban and tropical rainforest locations
(2011)
UV-LIF measurements were performed on ambient aerosol in Manchester, UK (urban city centre, winter) and Borneo, Malaysia (remote, tropical) using a Wide Issue Bioaerosol Spectrometer, version 3 (WIBS3). These sites are ...
Low-cost real-time multi-parameter bio-aerosol sensors (invited paper)
(2008-06-16)
Sensors that are able to provide reagent-free, continuous monitoring for potential bio-aerosol hazards are required in many environments. In general, increasing the number of optical and spectroscopic properties of individual ...