Search
Now showing items 1-2 of 2
Visualization study on operating performance of a dual compensation chamber loop heat pipe under acceleration condition
(2022-11-25)
In this article, a novel visual dual compensation chamber loop heat pipe (DCCLHP) under acceleration conditions was experimentally investigated. The working fluid was deionized water and the wick material was sintered ...
Experimental and numerical investigation on conjugate performance of fan and heat exchanger of helicopter oil cooling system
(2022-09-14)
In this article, a combined experimental and numerical study has been performed to investigate the operating performance of axial fan and oil cooling system. A test rig was established, and six types of plate-fin heat ...