Show simple item record

dc.contributor.authorMadden, A M
dc.contributor.authorMorgan, M Y
dc.date.accessioned2011-08-18T14:01:04Z
dc.date.available2011-08-18T14:01:04Z
dc.date.issued1994
dc.identifier.citationMadden , A M & Morgan , M Y 1994 , ' A comparison of skinfold anthropometry and bioelectrical impedance analysis for measuring percentage body fat in patients with cirrhosis ' , Journal of Hepatology , vol. 21 , no. 5 , pp. 878-83 . https://doi.org/10.1016/S0168-8278(94)80253-X
dc.identifier.issn0168-8278
dc.identifier.otherPURE: 309127
dc.identifier.otherPURE UUID: 1cc2896f-e3b5-4730-b14b-a755c8c80032
dc.identifier.otherPubMed: 7890906
dc.identifier.otherScopus: 0028132036
dc.identifier.urihttp://hdl.handle.net/2299/6311
dc.descriptionOriginal article can be found at: http://www.sciencedirect.com/science/journal/01688278 Copyright European Association for the Study of the Liver (EASL) [Full text of this article is not available in the UHRA]
dc.description.abstractPercentage body fat was determined by skinfold anthropometry and bioelectrical impedance analysis in 60 patients with cirrhosis, 30 of whom had overt fluid retention, and in 60 age- and sex-matched healthy volunteers. In the control population the mean +/- 1SD percentage body fat assessed using bioelectrical impedance analysis, 22.6 +/- 6.5%, and skinfold anthropometry, 22.5 +/- 6.9%, were comparable. However, there was considerable variation in individual values such that measurements made using bioelectrical impedance analysis could be from 9% less to 8% more than the corresponding anthropometric values. In patients with cirrhosis the mean percentage body fat assessed using bioelectrical impedance analysis, 24.4 +/- 8.9%, was significantly greater than the value obtained using skinfold anthropometry, 20.3 +/- 8.4% (p <0.01) for the whole group and for the subgroup of patients with fluid retention, 24.5 +/- 8.5% cf. 18.4 +/- 7.1% (p <0.005); estimates of body fat in the subgroup of patients without overt fluid retention were comparable between methods, 24.4 +/- 9.4% cf. 22.1 +/- 9.2%. In the whole patient group individual measurements made using bioelectrical impedance analysis could be from 10% less to 18% more than the corresponding anthropometric values; similar degrees of variation in individual values were observed in the two patient subgroups. Bioelectrical impedance analysis should not be used interchangeably with skinfold anthropometry for assessment of percentage body fat in patients with cirrhosis, irrespective of their state of hydration.en
dc.format.extent6
dc.language.isoeng
dc.relation.ispartofJournal of Hepatology
dc.subjectAdipose Tissue
dc.subjectAdult
dc.subjectAged
dc.subjectBody Composition
dc.subjectBody Fluids
dc.subjectElectric Impedance
dc.subjectFemale
dc.subjectHumans
dc.subjectLiver Cirrhosis
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectReference Values
dc.subjectReproducibility of Results
dc.subjectSkinfold Thickness
dc.titleA comparison of skinfold anthropometry and bioelectrical impedance analysis for measuring percentage body fat in patients with cirrhosisen
dc.contributor.institutionDepartment of Allied Health Professions and Midwifery
dc.contributor.institutionHealth & Human Sciences Research Institute
dc.description.statusPeer reviewed
rioxxterms.versionofrecordhttps://doi.org/10.1016/S0168-8278(94)80253-X
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record