Show simple item record

dc.contributor.authorWang, F.
dc.contributor.authorHelian, N.
dc.contributor.authorWu, S.
dc.contributor.authorGuo, Y.K.
dc.contributor.authorDeng, D.
dc.contributor.authorKhare, V.
dc.contributor.authorLiao, C.
dc.contributor.authorRashidi, M.
dc.contributor.authorParker, A.
dc.date.accessioned2013-01-14T15:58:58Z
dc.date.available2013-01-14T15:58:58Z
dc.date.issued2008
dc.identifier.citationWang , F , Helian , N , Wu , S , Guo , Y K , Deng , D , Khare , V , Liao , C , Rashidi , M & Parker , A 2008 , ' A Case for Redundant Arrays of Hybrid Disks (RAHD) ' , IEEE Transactions on Magnetics , vol. 44 , no. 11 , pp. 3738-3741 . https://doi.org/10.1109/TMAG.2008.2002531
dc.identifier.issn0018-9464
dc.identifier.otherPURE: 89327
dc.identifier.otherPURE UUID: f7f40a37-2819-4006-8a47-6b12078b2ac8
dc.identifier.otherdspace: 2299/2865
dc.identifier.otherScopus: 77955148179
dc.identifier.otherORCID: /0000-0001-6687-0306/work/64003371
dc.identifier.urihttp://hdl.handle.net/2299/9628
dc.description.abstractHybrid Hard Disk Drive was originally concepted by Samsung, which incorporates a Flash memory in a magnetic disk. The combined ultra-high-density benefits of magnetic storage and the low-power and fast read access of NAND technology inspires us to construct Redundant Arrays of Hybrid Disks (RAHD) to offer a possible alternative to today’s Redundant Arrays of Independent Disks (RAIDs) and/or Massive Arrays of Idle Disks (MAIDs). We first design an internal management system (including Energy-Efficient Control) for hybrid disks. Three traces collected from real systems as well as a synthetic trace are then used to evaluate the RAHD arrays. The trace-driven experimental results show: in the high speed mode, a RAHD outplays the purely-magnetic-disk-based RAIDs by a factor of 2.4–4; in the energy-efficient mode, a RAHD4/5 can save up to 89% of energy at little performance degradationen
dc.language.isoeng
dc.relation.ispartofIEEE Transactions on Magnetics
dc.subjectflash memory
dc.titleA Case for Redundant Arrays of Hybrid Disks (RAHD)en
dc.contributor.institutionCentre for Computer Science and Informatics Research
dc.contributor.institutionDepartment of Computer Science
dc.contributor.institutionSchool of Physics, Engineering & Computer Science
dc.description.statusPeer reviewed
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=77955148179&partnerID=8YFLogxK
rioxxterms.versionofrecordhttps://doi.org/10.1109/TMAG.2008.2002531
rioxxterms.typeJournal Article/Review
herts.preservation.rarelyaccessedtrue


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record