Finite element analysis of shear failure in supporting members of conventional and extended single-plate connections
Conventional single-plate (CSP) and extended single-plate (ESP) connections are widely used in steel buildings, yet the shear limit states of supporting members remain inadequately addressed. This study investigates shear yielding (SY) and shear rupture (SR) in supporting members of CSP and ESP connections using a nonlinear finite element model with ductile damage, validated against experimental data. Four configurations are analysed: CSP to H-column flange, CSP to box column, ESP to H-column web, and ESP to H-beam web. Results reveal that shear stresses propagate along inclined paths within the supporting member, forming shear planes at 35◦–45◦relative to the weld lines, contradicting conventional design assumptions, which significantly underestimate SY and SR strengths. A modified formulation is proposed to account for the actual active shear plane length. Parametric analyses quantify the shear stress spread angle and its dependence on geometry and loading. The proposed approach yields more accurate strength predictions and provides a rational basis for safer, more economical steel connection design.
| Item Type | Article |
|---|---|
| Identification Number | 10.1016/j.pes.2026.100411 |
| Additional information | © 2026 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ ). |
| Keywords | open - vor |
| Date Deposited | 19 Nov 2026 09:08 |
| Last Modified | 21 Nov 2026 02:07 |