Investigation on thermal performance of a combined compressed air and phase change temperature control system in underground refuge chamber

Pu, Lulu, Yang, Haishan, Zhou, Jiri, Ge, Liang, Zhang, Zujing, Mao, Ruiyong and Wu, Hongwei (2026) Investigation on thermal performance of a combined compressed air and phase change temperature control system in underground refuge chamber. International Communications in Heat and Mass Transfer (ICHMT), 180 (6): 112942. ISSN 0735-1933
Copy

The development of underground spaces is recognized as an effective solution to the resource shortages and traffic issues resulting from rapid urbanization. However, for underground spaces characterized by high population density, ensuring the safety of the indoor thermal environment has emerged as a critical factor to developing the resources of underground spaces. This paper examines the underground refuge chamber (URC) as a case study and investigates a safe and cost-effective combined temperature control scheme utilizing compressed air and phase change (CA-PC). A numerical model was developed, and its capability to reproduce the chamber-scale IAT response associated with ventilation and sensible heat transfer was evaluated against experimental data under stable and variable VTs. The model was subsequently used to investigate the effects of the number of phase change plates (PCPs), per capita ventilation rate (PCVR), ventilation temperature (VT), per capita building area (PCBA), and latent heat (LH) on the temperature control performance. The research findings indicate: (1) When employing mechanical ventilation for temperature regulation, the variation of indoor air temperature (IAT) over time follows an exponential function. (2) Under the investigated conditions, 10 PCPs with an LH of 250 kJ/kg can satisfy the 35 °C temperature criterion over the 96-h sheltering period. (3) A functional relationship was established between IAT over time, relative dimensions of chamber, ventilation parameters, and the number of PCPs. These research outcomes hold significant implications for guiding the installation of combined temperature control systems utilizing CA-PC in various URCs

mail Request Copy

picture_as_pdf
Accepted_Manuscript.pdf
subject
Submitted Version
lock_clock
Restricted to Repository staff only until 26 October 2027
Available under Creative Commons: BY-NC-ND 4.0

Request Copy

EndNote BibTeX Reference Manager Refer Atom Dublin Core OPENAIRE MODS OpenURL ContextObject Data Cite XML OpenURL ContextObject in Span METS ASCII Citation MPEG-21 DIDL HTML Citation RIOXX2 XML
Export

Downloads