Cost of Flexibility in NGCC-CCS Plants: Thermal Energy Storage versus Grid-Scale Battery Storage

Payel, Nizam U (2026) Cost of Flexibility in NGCC-CCS Plants: Thermal Energy Storage versus Grid-Scale Battery Storage. Masters thesis, University of Hertfordshire.
Copy

Great Britain’s transition towards a low-carbon electricity system increases the need for flexibility alongside variable renewable generation. In natural gas combined-cycle (NGCC) plants equipped with post-combustion carbon capture and storage (CCS), steam extraction for solvent regeneration couples heat demand with electrical output. This thesis compares plant-integrated thermal energy storage (TES) supplying the CCS reboiler with grid-scale lithium-ion battery energy storage systems (BESS) operating at the electrical interface. The analysis uses marginal cost of flexibility (MCF), defined as average incremental net cost per credited MWh-flex. TES flexibility is calculated from useful reboiler heat through an electrical-equivalent conversion factor; BESS flexibility is measured as AC electrical output. The study combines existing HOMER operating records with chronological storage calculations and financial assessment on an 8% real discount-rate basis over 25 years. Under the four-hour TES reference case, p40/p60 dispatch thresholds and an installed-cost assumption of £40/kWh-th, TES provides 12,776.80 MWh-flex annually at £42.91/MWh-flex. This cost includes charging opportunity cost and useful-discharge electricity value. The 100 MWh and 200 MWh headline BESS cases, each with a 50 MW converter, yield £54.41 and £58.49/MWh-flex, respectively. A separate SOC-constrained, price-responsive BESS sensitivity yields £50.13 and £59.85/MWh-flex under its own operating and accounting assumptions. With the headline BESS assumptions held fixed, TES installed-cost parity occurs at approximately £46.52/kWh-th and £48.83/kWh-th against the two respective BESS cases. TES therefore has the lower calculated reference MCF under the specified screening assumptions. The comparison remains conditional on physical integration, electrical headroom, dispatch, accounting scope and the retained price–thermal alignment limitation. An illustrative headroom restriction reverses the headline ordering. The study contributes an application of chronological storage accounting to CCS reboiler heat shifting, an installed-cost parity analysis and a comparison of the specified storage cases within explicit physical and economic boundaries.


picture_as_pdf
PAYEL Nizam final thesis.pdf
Available under Creative Commons: BY 4.0

View Download

EndNote BibTeX Reference Manager Refer Atom Dublin Core MODS OPENAIRE OpenURL ContextObject Data Cite XML MPEG-21 DIDL ASCII Citation RIOXX2 XML OpenURL ContextObject in Span HTML Citation METS
Export

Downloads